Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : Sinuo
Model Number : SN2210-2A
Certification : Calibration Certificate (Cost Additional)
Place of Origin : China
MOQ : 1
Price : Customized
Payment Terms : L/C, , T/T, Western Union, MoneyGram
Supply Ability : 100 pcs per month
Delivery Time : 3~5 Days
Packaging Details : Carton Box
Test Standard : IEC 60335-1 Clause 20.2
Stop Face : Ф50mm Circular
Applied Force : Can be customized
Probe Material : Stainless steel
Baffle Material : Nylon
Accessory : M6 thread and banana clip
IEC 60335-1 Clause 20.2 Similar to Test Probe B but Having a Ф50mm Circular Stop Face
Standards & Clauses:
IEC 60335-1 clause clause 20.2.
IEC61032:1997 “Protection of persons and equipment by enclosures-Probe for verification”
IEC60529:2013 “Degrees of protection provided by enclosure (IP code)”
Samples and Restrictions:
Household appliances, electrical accessories, lamps, etc.
Application:
To verify
a) protection of persons against access to hazardous parts inside the enclosure;
b) protection of the equipment inside the enclosure against ingree of solid foreign object.
Test Principle:
The similar to test probe B of IEC 61032 but having circular stop face with a diameter of 50 mm is used to distinguish the different protection levels of the electrical enclosure. After the current or force is applied to the probe, whether the probe can contact the live parts or internal parts, to determines whether the specimen is qualified or not.
Structure:
Technical Parameters:
Parameters /Model | SN2210-2 (Optional) | SN2210-2A | SN2210-2B (Optional) | SN2210-2T (Optional) |
Name | Standard test finger | Circular baffle test finger | Large baffle test finger | Standard test finger with force |
1 | 30±0.2 | 30±0.2 | 30±0.2 | 30±0.2 |
2 | 60±0.2 | 60±0.2 | 60±0.2 | 60±0.2 |
3 | 80±0.2 | 80±0.2 | 100±0.2 | 80±0.2 |
4 | 180±0.2 | 180±0.2 | ---- | 180±0.2 |
5 | R2±0.05 | R2±0.05 | R2±0.05 | R2±0.05 |
6 | S4±0.05 | S4±0.05 | S4±0.05 | S4±0.05 |
7 | 37o 0 -10’ | 37o 0 -10’ | 37o 0 -10’ | 37o 0 -10’ |
8 | 14 o 0 -10’ | 14 o 0 -10’ | 14 o 0 -10’ | 14 o 0 -10’ |
9 | Ф12 0 -0.05 | Ф12 0 -0.05 | Ф12 0 -0.05 | Ф12 0 -0.05 |
10 | Ф50 | Ф50 | ---- | Ф50 |
11 | 20±0.2 | ---- | ---- | 20±0.2 |
12 | Ф75±0.2 | Ф75±0.2 | Ф125±0.2 | Ф75±0.2 |
13 | 5±0.5 | 5±0.5 | ---- | 5±0.5 |
14 | ---- | ---- | ---- | 10-50N force |
15 | IEC61032.1 | IEC60335-1 | IEC60335-2-14 | IEC60529 |
![]() |